Electrical Wiring Diagrams
‑19‑
Note
● indicates shielded twisted pairs.
● [1] The range of the internal +24 V power supply is 20 V to 28 V, with maximum
operating current being 200 mA.
● [2] DI7 and DI8 are high‑speed DIs that must be used according to their functions
assigned.
● [3] The internal +5 V power supply supports a maximum current of 200 mA.
● [4] The DO power supply (voltage range: 5 V to 24 V) needs to be prepared by
users. The DO terminals support a maximum voltage of 30 VDC and a maximum
current of 50 mA.
● [5] Use shielded twisted pairs as frequency‑division output cables and full closed‑
loop input cables, with both ends of the cable shield connected to PE. Connect
GND to the signal ground of the host controller properly.