Electrical Design Guide
‑31‑
Servo drive model SV670****I
Recommended PVC Cable Model (at 40℃)
Size Model
Rated Input
Current
(A)
U, V, W, PE
Recommended
Model of Brake
Cable Lug
Recommended
Model of
Grounding Cable
Lug
Tightening
Torque
(N·m)
Size A
S1R6 1.1
GTVE10008 GTVE05008
TVR2–4
‑
S2R8 2.3 ‑
Size C
S5R5 4.4 ‑
S7R6 5.1 ‑
Size D S012 8.0 ‑
Size E
S018 8.7 ‑
S022 11.0 GTVE15008 GTVE10008 ‑
S027 23.8 GTVE25010 GTVE15008 ‑
Three‑phase 380 V
Size C
T3R5 2.4
GTVE10008 GTVE05008 TVR2–4
‑
T5R4 3.6 ‑
Size D
T8R4 5.6 ‑
T012 8.0 ‑
Size E
T017 12.0 TVS1.25‑4. GTVE10008 TVR1.25‑4. 1.36
T021 16.0 TVS2–4 GTVE10008 TNR2–4 1.36
T026 21.0 TVS3.5‑4. GTVE10008 TNR3.5‑4. 1.36
The following table lists the data for recommended cable lugs (manufacturer: Suzhou
Yuanli Metal Enterprise Co., Ltd) for your reference.
Table 3–6 TVR2‑4 cable lug
Model
D (mm) d2 (mm) B (mm)
Dimension Drawing
TVR 2‑4 4.5 4.3 8.5
Table 3–7 Specifications of motor output cables
MS1H1/H4 05B–10C (Applicable to 0.5 kW–1 kW)
Cable type Regular cable
Flexible cable
Oil‑resistant shielded flexible
cable
Cable model
S6‑L‑M/B***‑X.X S6‑L‑M/B***‑X.X‑T S6‑L‑M/B***‑X.X‑TS
Cable specifications
UL2517 (rated temperature:
105℃) 4Ex20AWG+ 2Cx24AWG
UL2517 (rated temperature:
105℃) 4Ex20AWG+ 2Cx24AWG
UL2517 (rated temperature:
105℃) 4Ex20AWG+ 2Cx24AWG
Power cable: 20AWG (0.52
mm
2
) OD of insulation: 1.7 mm
Power cable: 20AWG (0.52
mm
2
) OD of insulation: 1.7 mm
Power cable: 20AWG (0.52
mm
2
) OD of insulation: 1.7 mm
Brake cable: 24AWG (0.205
mm
2
) OD of insulation: 1.1.
mm
Brake cable: 24AWG (0.205
mm
2
) OD of insulation: 1.1.
mm
Brake cable: 24AWG (0.205
mm
2
) OD of insulation: 1.1.
mm