EasyManua.ls Logo

Inovance SV670P Series - Cable Routing and Grounding

Inovance SV670P Series
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical Design Guide
44
Table 3–12 Pin connection relation of the cable used for multi‑drive RS485 communication
(pins in 485 group used only)
RJ45 on the Drive Side (A) RJ45 on the Drive Side (B)
Communica
tion Type
Pin No.
Description
Communica
tion Type
Pin No.
Description
RS485
4 485+
RS485
4 485+
5 485‑ 5 485‑
8 GND 8 GND
Enclosure
PE (shield
layer)
Enclosure
PE (shield
layer)
In case of a large number of nodes, use the daisy chain mode for RS485
communication. Connect the reference grounds of RS485 signals of all the nodes (up
to 128 nodes) together.
Figure 3‑25 RS485 bus topology
Do not connect (GND) terminal to the CGND terminal of the drive. Failure to comply
may damage the machine.
Figure 3‑26 Daisy chain mode

Table of Contents

Other manuals for Inovance SV670P Series

Related product manuals