EasyManuals Logo

Intel S1200SPS User Manual

Intel S1200SPS
147 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #124 background imageLoading...
Page #124 background image
Intel® Server Board S1200SP Family Technical Product Specification
110 Revision 1.7
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor
Type
Event/
Reading
Type
Event Offset Triggers
Contrib.
To System
Status
Assert/
De-assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Hot-swap
Backplane 1
Temperature
(HSBP 1 Temp)
29h
Chassis-
specific
Tempe
rature
01h
Threshol
d
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
X
Hot-swap
Backplane 2
Temperature
(HSBP 2 Temp)
2Ah
Chassis-
specific
Tempe
rature
01h
Threshol
d
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
X
Hot-swap
Backplane 3
Temperature
(HSBP 3 Temp)
2Bh
Chassis-
specific
Tempe
rature
01h
Threshol
d
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
X
PCI Riser 2
Temperature
(PCI Riser 2 Temp)
2Ch
Platform-
specific
Tempe
rature
01h
Threshol
d
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
X
SAS Module
Temperature
(SAS Mod Temp)
2Dh
Platform-
specific
Tempe
rature
01h
Threshol
d
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
X
Exit Air
Temperature
(Exit Air Temp)
2Eh
Chassis and
Platform
Specific
Tempe
rature
01h
Threshol
d
01h
This sensor does not
generate any events.
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
X
Fan Tachometer
Sensors2
(Chassis specific
sensor names)
30h
3Fh
Chassis and
Platform
Specific
Fan
04h
Threshol
d
01h
[l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
M
-
Fan Present
Sensors
(Fan x Present)
40h
4Fh
Chassis and
Platform
Specific
Fan
04h
Generic
08h
01 - Device inserted
OK
As and De
-
Trigg
ered
Offse
t
Auto
-
Power Supply 1
Status
3
(PS1 Status)
50h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As and De
Trig
Offse
t
A
X
01 - Failure
Degraded
02 Predictive Failure
Degraded
03 - A/C lost
Degraded