Appendix C: Integrated BMC Sensor Tables Intel® Server Board S2600CO Family TPS
Revision 1.4
Intel order number G42278-004
122
Table 69. BMC Core Sensors
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type Event/
Reading
Type
Event Offset Triggers Contrib. To
System Status
Assert/
De-
assert
Readable
Value/
Offsets
Event
Data
Rearm Stand-
by
Power Unit Status
(Pwr Unit Status)
01h All
Power Unit
09h
Sensor
Specific
6Fh
00 - Power down
OK
As
and
De
– Trig Offset A X
02 - 240 VA power
down
Fatal
04 - A/C lost OK
05 - Soft power
control failure
Fatal
06 - Power unit failure
Power Unit Redundancy
Note1
(Pwr Unit Redund)
02h
Chassis-
specific
Power Unit
09h
Generic
0Bh
00 - Fully Redundant OK
As
and
De
– Trig Offset A X
01 - Redundancy lost Degraded
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
sufficient resources.
Transition from full
redundant state.
Degraded
04 – Non-redundant:
sufficient resources.
Transition from
insufficient state.
Degraded
05 - Non-redundant:
insufficient resources
Fatal
06 – Redundant:
degraded from fully
redundant state.
Degraded
07 – Redundant:
Transition from non-
redundant state.
Degraded