EasyManua.ls Logo

Intel S2600CO series

Intel S2600CO series
167 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Intel® Server Board S2600CO Family TPS Appendix G: Post Code Errors
Revision 1.4
Intel order number G42278-004
151
Table 81. Integrated BMC Beep Codes
Code Reason for Beep Associated Sensors
1-5-2-1 CPU socket population error CPU1 socket is empty, or sockets are populated
incorrectly
CPU1 must be populated before CPU2.
1-5-2-4 MSID Mismatch MSID mismatch occurs if a processor is installed
into a system board that has incompatible power
capabilities.
1-5-4-2 Power fault DC power unexpectedly lost (power good dropout)
– Power unit sensors report power unit failure
offset
1-5-4-4 Power control fault Power good assertion timeout – Power unit
sensors report soft power control failure offset
1-5-1-2 VR Watchdog Timer VR controller DC power on sequence was not
completed in time.
1-5-1-4 Power Supply Status The system does not power on or unexpectedly
powers off and a Power Supply Unit (PSU) is
present that is an incompatible model with one or
more other PSUs in the system.

Table of Contents

Related product manuals