Intel® Server Board S3420GP User Guide 37
3. Move the jumper from the default operating position (covering pins 1 and 2) to the
reset / clear position (covering pins 2 and 3).
Figure 8. CMOS Recovery Jumper
4. Wait five seconds.
5. Move the jumper back to default position, covering pins 1 and 2.
6. Close the server chassis.
7. Reconnect the AC power and power up the system. The CMOS is cleared and can
be reset by going into the BIOS setup.
Updating the Integrated BMC (Intel
®
Server Board
S3420GPLX and S3420GPLC)
Figure 9. BMC Force Update Jumper
3
2
Default
CLEAR
CMOS
J1F5
CMOS
Clear
AF003182
3
2
Default
Enabled
J1A2
BMC
Force
Update
AF003291