7. Environmental Limits
7.1 System Office Environment
Table 18. Intel
®
Storage System SSR212MA System Office Environment Summary
Parameter Limits
Operating Temperature 10
degrees celcius to +35
degrees celcius with the maximum rate of
change not to exceed 10 degrees celcius per hour.
Non-Operating Temperature -40
degrees celcius to +70
degrees celcius
Non-Operating Humidity 95%, non-condensing at 35 degrees celcius
Acoustic noise 7.0 BA (Rackmount) in an idle state at typical office ambient
temperature. (23 ± degrees celcius)
Operating Shock No errors with a half sine wave shock of 2 Giga (1.024 x 10
9
) (G) (with
11 millisecond duration)
Package Shock Operational after a 30 inch free fall, although cosmetic damage may be
present (chassis weight 30 lbs)
Electrostatic Discharge (ESD) ±15 Kilovolt (KV) per Intel
®
Environmental test specification
System Cooling Requirement
in British Thermal Units (BTU)
per Hour
2275 BTU/hour
7.2 System Environmental Testing
The system has been tested per the Intel
®
Environmental Standards Handbook, Intel document
number 662394-03. These tests include:
• Temperature Operating and Non-Operating
• Humidity Non-Operating
• Packaged and Unpackaged Shock
• Packaged and Unpackaged Vibration
• AC Voltage, Frequency and Source Interrupt
• AC Surge
• Acoustics
• ESD