Intel® Storage System SSR212MA Environmental Limits
Revision 1.4 37
7.3 Environmental Limits
The following table summarizes environmental limits, both operating and non-operating.
Table 19. Intel
®
Storage System SSR212MA Operating and Non-Operating Environmental Limits
Temperature Specification
Non-operating -40 degrees celcius to 70 degrees celcius
Operating Temperature 10 degrees celcius to 35 degrees celcius
Thermal Map Must not exceed maximum Integrated Circuit (IC) junction temperature as specified
in the component data sheets (CPDs).
Thermal Shock Specification
Non-operating -40 degrees celcius to 70 degrees celcius
Humidity Specification
Non-operating 92% Relative Humidity (RH) at +50 degrees celcius
Vibration Specification
Non-Operating:
2.2 Grms 5-500Hz for the unpackaged and 1.09 Grms 5-500Hz for the
packaged.
Shock Specification
Non-operating 25 G, 11 millisecond (msec)
ESD Specification
Operating Test (air) to 15 KV and (contact) to 2-8KV with limited errors.
EMI Specification
Operating Required to meet EMI emission requirements, tested as part of system.