154  Advisor Advanced ATSx000A(-IP) Installation and Programming Manual 
8.6.3 EE full set 
 
If the option is set to Yes and the user exits premises during part set exit time 
(which causes activation of entry/exit zone), part set state changes to full set.  
Note: The functionality works only if there is exit time defined for part set. It 
means that area part set exit time defined in “5.n.2 Exit time” on page 113 must 
be longer than 0. 
8.6.4 PS1 name 
8.6.5 PS2 name 
 
Use these menus to change the default part set prompts “Part set 1” and “Part 
set 2”. Empty string is equal to the default prompt. 
See Advisor Advanced User Manual for more details on partial setting. 
Panel and AB options 
8.7 Panel and AB options 
 
The Panel and AB options menu allows you to change particular system values. 
See also “Initial start-up” on page 43. 
If particular settings are changed in this menu, you are prompted to confirm those 
changes while trying to leave this menu. See “Confirmation of changes” on 
page 40. 
8.7.1 Panel name 
 
The Panel name menu lets you change the panel name. 
8.7.2 Panel language 
 
2 Panel language 
    >ENGLISH UK< 
The Panel language menu lets you change the panel language. 
Caution: Changes of the following authorization options will cause deleting of all 
user PINs, and setting default PINs of two predefined users. See also “Initial 
start-up” on page 43, and “Predefined users” on page 83.