Advisor Advanced ATSx000A(-IP) Installation and Programming Manual  233 
Zone types 
The following zone types are available. 
1. Alarm 
Generates no alarm when the area is unset.  
Generates an alarm when the area is set. 
Example: Internal door, PIR (motion detector). 
2. Entry/Exit 1 
Generates no alarm when the area is unset.  
When the area is set, the exit timer starts and activating the zone generates no 
alarm. If the zone is activated when the exit time has expired, the entry timer 
starts. Only when the entry time has expired, an alarm is generated. 
Example: Front door. 
You need to program the entry/exit time. See “5 Area menu” on page 113 for 
more information. 
3. Access 
Generates no alarm when the area is unset.  
Generates an alarm when the area is set, and the no exit timer or entry timer is 
not running. 
Example: PIR at entrance with a door contact on the entry door. 
You need to program the entry/exit time. See “5 Area menu” on page 113 for 
more information. 
4. Fire 
Generates a fire alarm regardless of the status of the area. 
Fire alarm causes pulsing siren sound. This alarm has higher priority than an 
intrusion alarm. 
Example: Smoke detector. 
5. Panic 
Generates a panic alarm regardless of the status of the area.  
Example: panic button. 
See also “8.8.1 Panic mode” on page 158. 
6. 24H 
Generates an intrusion alarm regardless of the status of the area. 
7. Tamper 
Generates a tamper alarm regardless of the status of the area.