Advisor Advanced ATSx000A(-IP) Installation and Programming Manual  239 
Options affected by other regulations 
ACPO policy 
Required settings are all EN 50131 Grade 2 settings with the following 
modifications: 
•  5.n.7 Entry alarms, Delayed 
•  8.2.4 Engineer reset, tamper enabled 
•  8.7.7 Alarm confirm: 
- AB mode, enabled for all relevant areas 
- AB time, 30 min minimum, 60 min maximum 
- EE Confirm, enabled 
- TA confirm, enabled 
Note: ACPO policy allows a higher level manager to become a level 3 user. Also, 
level 3 user menu access may be allowed without level 2 user authorization if it is 
provided by appropriate written agreement from the customer. 
INCERT policy 
Required settings: 
•  Isolate for End Users option disabled in 3.2.n.5 User group options 
•  Full Set/Part Set/Unset/Forced Set for Installer disabled in 3.2.n.5 User group 
options 
•  8.2.4 Engineer reset, tamper enabled 
•  8.4.1 RTS options, all enabled except FTC, Pending Alarms, and Zone 
technical alarm, that are optional 
•  RTS for Battery Fault enabled in 8.4.1 RTS options 
•  Inhibit for Battery Fault disabled in 8.4.2 Inhibit includes 
•  PIN length should be 6 digits minimum. See also “8.7.5 PIN length”.