104  Advisor Advanced ATSx000A(-IP) Installation and Programming Manual 
Notes 
•  This option is only available for panic type zones. See “Zone types” on page 
233. 
•  The option is only available when Panic mode is set to Silent. Otherwise 
panic alarm is always reported as PA event. See “8.8.1 Panic mode” on page 
158. 
Shock sensor options 
4.1.n.7 Gross and Pulse options 
 
The Gross and Pulse options are valid if the “4.1.n.6.12 Shock sensor” 
functionality (see page 99) for this zone is set to Yes. 
4.1.n.7.1 Pulse count 
 
Set the number of pulses within a time window that will activate the zone. 
The following values are applicable: 
•  1 to 9: number of pulses within 30 seconds that activates the zone. Only 1 
count per second is taken into account. 
•  0: the counter functionality is disabled. 
4.1.n.7.2 Gross level 
 
Use the Gross level option to set the level for a single pulse that activates the 
zone. The following values are applicable: 
•  1 to 9: Gross attack level where 1 means high sensitivity, and 9 means low 
sensitivity 
•  0: Gross level is disabled 
Gross level can be checked in menu “1.2.2 ShockSens test” (see page 49). 
Wireless sensor options 
4.1.n.7 RF details 
 
The RF details menu allows you to program a wireless device manually, or 
remove it from the wireless expander.