Advisor Advanced ATSx000A(-IP) Installation and Programming Manual  103 
See also “Outputs” on page 120. 
4.1.n.6.29 Held open 
  
The menu defines if this zone raises a “zone open too long” alarm while held 
open longer than for a defined period. 
The held open period is defined in “8.1.4.6 Held open time” on page 142. 
Note: If the option is active, the option “4.1.n.6.4 Double knock” on page 97 is 
not available. 
4.1.n.6.30 EE set check 
 
If set to yes, entry/exit or access zone must be in a normal state when setting the 
area. Otherwise, the user is not allowed to set premises until the problem is 
solved. 
The option is only available for entry/exit and access type zones. 
4.1.n.6.31 Alarm in PS1 
  
If the option is set to yes, entry/exit zone becomes an alarm zone during part 
set 1. 
Notes 
•  The option is only available for entry/exit type zones. See “Zone types” on 
page 233 
•  The zone must be included into part set 1. See “4.1.n.6.2 Excl. in PS1” on 
page 97. 
•  Zone functionality does not change if the same zone belongs to an area in full 
set state. 
4.1.n.6.32 Alarm in PS2 
The same as “4.1.n.6.31 Alarm in PS1” above, but for part set 2. 
4.1.n.6.33 Report as 
  
33 Report as 
    >Panic (PA)< 
Defines how panic alarm is reported to central stations. 
•  Report as panic: PA event is reported. 
•  Report as duress: HA event is reported. 
See “Reporting codes used in Advisor Advanced” on page 223 for details.