Advisor Advanced ATSx000A(-IP) Installation and Programming Manual  157 
8.7.7.5 EE inhibit 
 
5 EE inhibit 
    >Entry/Exit< 
The EE inhibit option defines the functionality of the access zone in the area (if 
available) when an entry/exit (EE) zone is inhibited at the end of the AB time 
(auto-inhibit function). The following values are allowed: 
•  Entry/Exit: an access zone acts as an entry/exit zone, if the entry/exit zone is 
inhibited.  
•  Access: an access zone does not change its functionality and causes an 
alarm when activated while no EE timer is running.  
8.7.7.6 TA confirm 
 
If the TA confirm option is set to Yes, tamper alarm (TA) can report a B-alarm for 
burglary alarm (BA), and vice versa. 
8.7.7.7 Sirens 
 
The Sirens menu allows you to select per area when the siren is activated: on A-
alarm or on B-alarm. 
Note: Option B-alarm is valid only if AB mode is enabled. See “8.7.7.1 AB mode” 
on page 155. 
8.7.7.8 Call CS message 
 
If the Call central station message option is set to Yes, in case of alarm the 
keypad displays a message with advice for the user to call the central station 
when a report has been sent. 
8.7.7.9 Reporting delayed 
 
Enable a 30-second delay before alarm reporting required by ACPO regulations. 
8.7.8 Easy unset 
 
If enabled, you can unset premises entering a PIN or badging a valid card 
without pressing any other keys.