30 Installation Guide
Protocol settings
Use SW2 switches numbers 3, 4 and 5 to set the PTZ dome
protocol. Refer to Table 2 below:
Table 7: Set the dome protocol
Protocol
SW2 switch no.
3 4 5
UTC RS-485 OFF OFF OFF
PROTOCOL_PELCO_P ON OFF OFF
PROTOCOL_PELCO_D OFF ON OFF
PROTOCOL_DIGIPLEX ON ON OFF
PROTOCOL_RS422_ASCII OFF OFF ON
PROTOCOL_BOSCH_CODE OFF ON ON
PROTOCOL_AD_CODE ON ON ON
HD-TVI mode settings
Use SW2 switch number 7 to set the HD-TVI mode of the PTZ
dome. HD-TVI Mode 1.0 and HD-TVI Mode 2.0 are two
standards to transfer HD-TVI signals. For HD-TVI Mode 1.0, it
supports short transmission distance with wide bandwidth
while for HD-TVI Mode 2.0, it supports long transmission
distance with narrow bandwidth. Refer to Table 8 below: