10
5.2. Changing Parameters
Procedure
Power
Press and hold the
Press the
The and
can be used to select the desired parameter
Select the required parameter, e.g. P1
Press the
Use the
and keys to adjust the value, e.g. set to 10
Press the
The parameter value is now adjusted and automatically stored. Press the
return to operating mode
5.3.
Advanced Keypad Operation Short Cuts
Function When
Display shows...
Fast Selection of
Parameter Groups
Note : Parameter Group
Access must be
enabled
P1-14 = 101
P
PP
Px-
--
-xx
P
PP
Px-
--
-xx
Select lowest Group
Parameter
P
PP
Px-
--
-xx
Set Parameter to
minimum value
Any numerical value
(Whilst editing a
parameter value)
Adjusting individual
digits within a
parameter value
Any numerical valu
e
(Whilst editing a
parameter value)
5.4. Reset All Parameters to
Factory Default Settings
To reset all drive paramete
rs to factory default settings
acknowledge and reset the drive.
Optidrive Plus 3
GV
Compact - User Guide
www.invertek.co.uk
Power
on Drive
Press and hold the
for >2 seconds
Press the
Key
can be used to select the desired parameter
Select the required parameter, e.g. P1
-02
Press the
button
and keys to adjust the value, e.g. set to 10
Press the
key
The parameter value is now adjusted and automatically stored. Press the
key for >2 seconds to
return to operating mode
Advanced Keypad Operation Short Cuts
Display shows...
Press... Result
+
The next highest
Parameter group is
selected
+
The next lowest
Parameter group is
selected
+
The first parameter of a
group is selected
Any numerical value
+
The parameter is set to
the minimum value
e
+
Individual parameter
digits can be adjusted
Factory Default Settings
rs to factory default settings
, press , and
for >2s. The display shows
Display shows...
Stop
StopStop
Stop
P
PP
P1-01
1-011-01
1-01
P
PP
P1-0
1-01-0
1-02
22
2
P
PP
P1-0
1-01-0
1-03
33
3
etc...
P
PP
P1-0
1-01-0
1-02
22
2
0.0
0.00.0
0.0
10.0
10.010.0
10.0
P
PP
P1-0
1-01-0
1-02
22
2
key for >2 seconds to
Stop
StopStop
Stop
Example
Display shows
P
PP
P1-10
1-101-10
1-10
Press +
Display shows
P2
P2P2
P2-01
-01-01
-01
Display shows
P2
P2P2
P2-
--
-26
2626
26
Press +
Display shows
P
PP
P1-01
1-011-01
1-01
The first parameter of a
Display shows
P
PP
P1-10
1-101-10
1-10
Press +
Display shows
P
PP
P1-01
1-011-01
1-01
The parameter is set to
When editing P1-01
Display shows
5
55
50
00
0.0
00
0
Press +
Display shows
0
00
0.0
00
0
Individual parameter
digits can be adjusted
When editing P1-10
Display shows
0
00
0
Press +
Display shows
_
__
_0
00
0
Press
Display shows
10
1010
10
Press +
Display shows
_
__
_10
1010
10
Press
Display shows
110
110110
110
Etc...
for >2s. The display shows
ìP-dEFî
. Press the button to

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Invertek Drives Optidrive Plus 3GV Compact and is the answer not in the manual?

Invertek Drives Optidrive Plus 3GV Compact Specifications

General IconGeneral
BrandInvertek Drives
ModelOptidrive Plus 3GV Compact
CategoryInverter
LanguageEnglish

Related product manuals