Goodrive300-01 inverter for air compressor Function parameters
-14-
Function
code
Name
Detailed instruction of parameters
Default
value
Modif
y
The setting range: P00.05~P00.03 (Max. output
frequency)
P00.05
Lower limit of
running frequency
The lower limit of running frequency is the lower limit
of output frequency of the inverter.
If the set frequency is lower than the lower limit, the
inverter runs at the lower limit.
Note: Max. output frequency Upper limit
frequency Lower limit frequency
The setting range: 0.00Hz~P00.04 (Upper limit of
running frequency)
0.00Hz
P00.06
A frequency
command
Note: Frequency A and frequency B cannot use the
same frequency setting mode. The frequency source
can be set by P00.09.
0: Keypad
Modify the value P00.10 (set the frequency by
keypad) to modify the frequency by the keypad.
1: AI1
2: AI2
3: AI3
Set the frequency by analog input terminals.
Goodrive300-01 series inverters provide 3 analog
input terminals as the standard configuration, of
which AI1/AI2 are the voltage/current option
(0~10V/0~20mA) which can be shifted by jumpers;
AI3 is voltage input (-10V~+10V).
Note: When analog AI1/AI2 select 0~20mA input,
the corresponding voltage of 20mA is 10V.
100.0% of the analog input setting corresponds to
the maximum output frequency (P00.03) in forward
direction and -100.0% corresponds to the maximum
frequency (P00.03) in reverse direction.
4: High-speed pulse HDI
The frequency is set by high-speed pulse terminals.
Goodrive300-01 series inverters provide 1 high
speed pulse input as the standard configuration. The
pulse frequency range is 0.0~50.00kHz.
100.0% of the high-speed pulse input setting
corresponds to the maximum output frequency
(P00.03) in forward direction and -100.0%
0
P00.07
B frequency
command
2