Goodrive300-01 inverter for air compressor Function parameters
-37-
Detailed instruction of parameters
Voltage increasing time is the time when the inverter
accelerates from the output minimum voltage to the
output maximum voltage.
Voltage decreasing time is the time when the inverter
decelerates from the output maximum voltage to the
output minimum voltage.
The setting range: 0.0~3600.0s
Set the upper and low limit of the output voltage.
The setting range of P04.31: P04.32~100.0% (motor
rated voltage)
The setting range of P04.32: 0.0%~P04.31
Flux weakening
coefficient at
constant power
The parameter is used to adjust the output voltage of
inverter in SVPWM control mode at flux weakening.
Note: Invalid in constant torque mode.
The setting range of P04.33: 1.00~1.30
Reactive
close-loop
proportionality
coefficient
Reactive
close-loop integral
coefficient
P05 Group Input terminals
S1 terminals
function selection
0: No function
1: Forward rotation operation (FWD)