Goodrive300-01 inverter for air compressor Function parameters
-39-
Detailed instruction of parameters
43: Oil filter blockage signal
44: Separator blockage signal
45: Precision separator signal
46: External fault 1
47: External fault 2
48~63: Reserved
The function code is used to set the polarity of the
input terminals.
Set the bit to 0, the input terminal is anode.
Set the bit to 1, the input terminal is cathode.
The setting range: 0x000~0x1FF
Set the sample filter time of S1~S8 and HDI
terminals. If the interference is strong, increase the
parameter to avoid the misoperation.
0.000~1.000s
Virtual terminals
setting
Enable the input function of virtual terminals at the
communication mode.
0: Virtual terminals are invalid
1: MODBUS communication virtual terminals are
valid
2: Reserved
3: Reserved
4: Reserved
Terminals control
running mode
Set the operation mode of the terminals control
0:2-wire control 1, comply the enable with the
direction. This mode is widely used. It determines
the rotation direction by the defined FWD and REV
terminals command.