Goodrive300-01 inverter for air compressor Function parameters
-39-
Function
code
Name
Detailed instruction of parameters
Default
value
Modif
y
43: Oil filter blockage signal
44: Separator blockage signal
45: Precision separator signal
46: External fault 1
47: External fault 2
48~63: Reserved
P05.10
Polarity selection
The function code is used to set the polarity of the
input terminals.
Set the bit to 0, the input terminal is anode.
Set the bit to 1, the input terminal is cathode.
BIT8
BIT7
BIT6
BIT5
HDI
S8
S7
S6
BIT4
BIT3
BIT2
BIT1
BIT0
S5
S4
S3
S2
S1
The setting range: 0x000~0x1FF
0x000
P05.11
ON-OFF filter
time
Set the sample filter time of S1~S8 and HDI
terminals. If the interference is strong, increase the
parameter to avoid the misoperation.
0.000~1.000s
0.300s
P05.12
Virtual terminals
setting
Enable the input function of virtual terminals at the
communication mode.
0: Virtual terminals are invalid
1: MODBUS communication virtual terminals are
valid
2: Reserved
3: Reserved
4: Reserved
0
P05.13
Terminals control
running mode
Set the operation mode of the terminals control
0:2-wire control 1, comply the enable with the
direction. This mode is widely used. It determines
the rotation direction by the defined FWD and REV
terminals command.
0