Goodrive300-01 inverter for air compressor Function parameters
-42-
Function
code
Name
Detailed instruction of parameters
Default
value
Modif
y
P05.22
Switch-on delay
of S5 terminal
0.000s
P05.23
Switch-off delay
of S5 terminal
0.000s
P05.24
Switch-on delay
of S6 terminal
0.000s
P05.25
Switch-off delay
of S6 terminal
0.000s
P05.26
Switch-on delay
of S7 terminal
0.000s
P05.27
Switch-off delay
of S7 terminal
0.000s
P05.28
Switch-on delay
of S8 terminal
0.000s
P05.29
Switch-off delay
of S8 terminal
0.000s
P05.30
Reserved
0.000s
P05.31
Reserved
0.000s
P05. 32
Lower limit of AI1
The function code defines the relationship between
the analog input voltage and its corresponding set
value. If the analog input voltage exceeds the set
minimum or maximum input value, the inverter will
count at the minimum or maximum one.
When the analog input is the current input, the
corresponding voltage of 0~20mA is 0~10V.
In different cases, the corresponding rated value of
100.0% is different. See the application for detailed
information.
The figure below illustrates different applications:
0.00V
P05.33
Corresponding
setting of the
lower limit of AI1
0.0%
P05.34
Upper limit of AI1
10.00V
P05.35
Corresponding
setting of
the upper limit of
AI1
100.0%
P05.36
AI1 input filter
time
0.100s
P05.37
Lower limit of AI2
0.00V
P05.38
Corresponding
setting of the
lower limit of AI2
0.0%
P05.39
Upper limit of AI2
10.00V
P05.40
Corresponding
setting of
the upper limit of
AI2
100.0%