Note:
a) The one-key-to-set key is available once wiring is done according to above diagram.
b) PT100 of GD300-01 in above diagram is selected by P18.03. It is set as temp detection terminal
(PTA, PTB and PTC) by default; temp transmitter can be set according to field needs
(P18.03=0), however, generally, temp transmitter needs no setup.
c) Above wiring makes phase sequence detection function available, and users can set this
function on the touch screen as needed;
d) In the internal 220V power of PP100, there is only 30W power can be used to supply solenoid
valve coil and contactor coil, please do not apply large-power load here.
e) Please refer to Operation manual for PP100-01 air compressor power module on how to use
PP100 power module.
f) Please refer to User manual for VT6070E series touch screen HMI on how to use the touch
screen