Goodrive300-LIFT series inverter Function parameters
-62-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P10.09
Current loop
filter coefficient
Bit02: Current instruction filter count
(compensation completion phase)
Bit3-5: Current instruction filter count
(compensation phase)
Bit6: Speed detection switching( 0:
segmentation; 1 observer)
Bit7-8: Current sampling filter count
Bit14: Enable temperature-based carrier
frequency decrease (0: Enable; 1: Disable)
Bit215: Reserved
0
P10.10
Reserved
065535
0
P10.11
Reserved
065535
0
P11 Group Protective parameters
P11.00
Phase loss
protection
0x0000x111
LED ones:
0: Disable input phase loss protection
1: Enable input phase loss protection
LED tens:
0: Disable output phase loss protection
1: Enable output phase loss protection
LED hundreds:
0: Disable hardware input phase loss protection
1: Enable hardware input phase loss protection
0x110
P11.01
Frequency-decre
asing at sudden
power loss
0: Disable
1: Enable
0