Goodrive350 IP55 High-ingress Protection Series VFD Function parameter list
-124-
7: PID control
8: Modbus/Modbus TCP communication
9: PROFIBUS/CANopen/DeviceNet
communication
10: Ethernet communication
11: High speed pulse HDIB
12: Pulse train AB
13: EtherCAT/PROFINET/EtherNet IP
communication
14: Programmable card
15: Reserved
Reference
object of B
frequency
command
0: Max. output frequency
1: A frequency command
Combination
mode of
setting source
0: A
1: B
2: (A+B)
3: (A-B)
4: Max. (A, B)
5: Min. (A, B)
When A and B frequency commands are set by
keypad, the value is the initial digital set value of
the VFD frequency.
Setting range: 0.00 Hz–P00.03 (max. output
frequency)
Acceleration time is the time needed for
accelerating from 0Hz to max. output frequency
(P00.03).
Deceleration time is the time needed from
decelerating from max. output frequency (P00.03)
to 0Hz.
The Goodrive350 IP55 high-ingress protection
series VFD defines four groups of acceleration and
deceleration time, which can be selected via
multi-function digital input terminals (P05 group).
The acceleration/deceleration time of the VFD is
the first group by default.
Setting range of P00.11 and P00.12: 0.0–3600.0s
0: Run in default direction
1: Run in reverse direction
2: Reverse running is prohibited