Function
code
Name
Detailed parameter description
Default
value
Modi
fy
mode
0: A/B quadrature pulse; A precedes B
1: A: PULSE; B: SIGN
If channel B is of low electric level, the edge counts
up; if channel B is of high electric level, the edge
counts down.
2: A: Positive pulse
Channel A is positive pulse; channel B needs no
wiring
3: A\B dual-channel pulse; channel A pulse edge
counts up, channel B pulse edge counts down
Tens: Pulse direction
Bit0: Set pulse direction
0: Forward
1: Reverse
Bit1: Set pulse direction by running direction
0: Disable, and BIT0 is valid;
1: Enable
Hundreds: Pulse/direction frequency-doubling
selection (reserved)
0: No frequency-doubling
1: Frequency-doubling
Thousands: Pulse control selection
Bit0: Pulse filter selection
0: Inertia filter
1: Average moving filter
Bit1: Overspeed control
0: No control
1: Control
P21.02
Position loop
gain 1
0400.0
20.0
P21.03
Position loop
gain 2
0400.0
30.0
P21.04
Switch-over
mode of position
loop gain
0: No switch-over
1: Torque command
2: Speed command
35: Reserved
0
P21.05
Torque command
level during
position gain
0.0100.0% (rated motor torque)
10.0%