Goodrive350 series high-performance multi-function inverter Appendix D
-319-
To ensure safety, you can configure an electromagnetic contactor on the input side to control the
switch-on and switch-off of the main circuit power, so that the input power supply of the inverter can
be effectively cut off when a system fault occurs.
D.5.1 Breakers and electromagnetic contactors for AC 3PH 380V (-15%)440V (+10%)
Inverter model
Fuse (A
Breaker
(A)
Rated current of the
contactor (A)
GD350-1R5G-4
1
16
10
GD350-2R2G-4
17.4
16
10
GD350-004G-4
30
25
16
GD350-5R5G-4
45
25
16
GD350-7R5G-4
60
40
25
GD350-011G-4
78
63
32
GD350-015G-4
105
63
50
GD350-018G-4
114
100
63
GD350-022G-4
138
100
80
GD350-030G-4
186
125
95
GD350-037G-4
228
160
120
GD350-045G-4
270
200
135
GD350-055G-4
315
200
170
GD350-075G-4
420
250
230
GD350-090G-4
480
315
280
GD350-110G-4
630
400
315
GD350-132G-4
720
400
380
GD350-160G-4
870
630
450
GD350-185G-4
1110
630
580
GD350-200G-4
1110
630
580
GD350-220G-4
1230
800
630
GD350-250G-4
1380
800
700
GD350-280G-4
1500
1000
780
GD350-315G-4
1740
1200
900
GD350-350G-4
1860
1280
960
GD350-400G-4
2010
1380
1035
GD350-500G-4
2505
1720
1290
Note: The accessory specifications described in the preceding table are ideal values. You can select