33
3. Use the / buttons to set a manual operation run time ranging
from 1 minute to 5.9 hours.
4. Press the Manual button to start the operation.
5. If this is the only station to be run manually, skip step 6 and
continue at step 7 below.
6. To add additional stations to the manual run operation, repeat steps
2 through 4 as needed, then continue at step 7.
Note: Depending upon the Stack/Overlap setting, additional
stations selected (beyond the one or three option setting) will regis-
ter as OFF when entered with the Manual button. However, they will
be placed (stacked) in the manual sequence to run.
7. Turn the Dial to the Current Time position.
Note: Once started, the station sequence can be manually advanced
by pressing the Manual button.
Note: To terminate manual watering operations, place the Function
switch momentarily in the OFF or Stop position.
Clear Program Memory
The Clear Program Memory feature enables you to safely clear the
automatic watering program settings defined for a specific Program
without affecting any remaining Program information. The memory erase
function applies only to the specified Program, leaving the remaining
Programs intact.
Important: The “Clear Program” function completely erases
all user-defined programming information from the selected
Program including: start times, run times, and watering day
schedule.
Note: To reset the controller (all Programs) to factory default
settings, refer to “Restore Rain Dial-R to Factory Default Settings” on
page 35.
1. Place the Function switch in the Set Programs position.
2. Place the Program switch to select A, B or C.
3. Turn the Dial to the Skip Days - Special Functions position.
4. Press the Manual button repeatedly to display CLr (Clear).
5. Press the button one time. The display will show the prompt:
CL? (Clear?).