Specications
Input Power
Outdoor Model: 120 VAC 60 Hz, 30 VA (Domestic)
230/240 VAC, 50 Hz, 30VA
(International)
Indoor Model: 24 VAC, 60 Hz, 30 VA (Domestic)
(from plug-in transformer) 24 VAC, 50 Hz, 30 VA
(International and Australian)
All Models:
Station Output: 24 VAC at 0.5A, 1.0A (maximum total)
Master Valve/Pump Start Relay Output: 24 VAC at 0.375A
2.0A Slow-blow Fuse
Battery Back-up (time, day and date)
Operating temperature range: 32˚F to 140˚F (0˚C to 60˚C)
Caution: The Rain Dial is designed to operate 24 VAC valve solenoids
rated at 0.25A (6 VA). Total current load during operation must not exceed
1.0A. A maximum of two solenoids per station terminal may be used if the
total station load does not exceed 0.5A. No more than three solenoids (plus
MV/Pump circuit) should operate concurrently. In irrigation systems where
multiple controllers are used, each controller must utilize a separate valve
common circuit.