Technical Specifications
Copyright ©ITECH Electronic Co., Ltd. 130
Voltage RMS
Resolution
0.01
Accuracy
DC,16Hz
~
500Hz
<
0.1%+0.1%
F.S.
Temperature
< 100ppm/
℃
F.S.
Current RMS
Range
0
~
810
A
Resolution
0.1
A
Accuracy
DC,16Hz
~
150Hz
<
0.1% + 0.2%
F.S.
150.01Hz
~
500Hz
<
0.2% + 0.3%
F.S.
Temperature
< 200ppm/
℃
F.S.
Peak current
Range
0
~
2430
A
Resolution
1
Accuracy
<
0.3% + 0.6%
F.S.
Active power
Range
0
~
135
kW
Resolution
0.001
kW
Accuracy
<
0.4% +0.4%
F.S.
Reactive power
Range
0
~
135
kVAR
Resolution
0.001
kVAR
Accuracy
<
0.4% +0.4%
F.S.
Apparent power
Range
0
~
135
KVA
Resolution
0.001
KVA
Accuracy
<
0.4% +0.4%
F.S.
CF
Range
1
~
5
Resolution
0.01
PF
Range
0.1
~
1
Resolution
0.01
Accuracy
1%F.S.
Harmonic
measuremen
t
Max.
50/60Hz
up to 50
orders
Regenerative power
Max.
Regenerativ
e power
135k
VA
ITHD
< 5%
Other
Efficiency
typ
88%
Protection
OVP
,
POVP
,
OCP
,
POCP
,
+OPP
,
-OPP
,
OTP
,
FAN
,
ECP
,
Sense
,
UVP
,
FE
dimension
600.0000mm
(
W
)
*1919
(
H
)
*841mm
(
D
)(
909mm include cover)
Weight
546.5kg
Working
temperature
0
℃
-50
℃
Programming
response
time
2ms
Communication
interface
Built-in USB/CAN/LAN/Digital IO interface, optional GPIB / Analog&RS232
*1 ( 200
~
220 ) ±10%, 3 phase AC input, 60% of the rated power output for 12Kw and above models.
*2 Under the output frequency of 50Hz/60Hz, the maximum CF is 5 without exceeding the peak current; under the condition of full current and full
power, the maximum CF is 3.
*3 When frequency <150Hz, the minimum current for test need to be 1%F.S. frequency >150Hz, the minimum current for test need to be 3%F.S.
*4When loopSpeed Low is low
,
it can better complied DUT's characteristics
;
When LoopSpeed is High
,
the dynamic response time is
*5 Frequency <150Hz, the specification is meet.
*6 In the rectifier load mode, the setting range of phase Angle is related to CF. The larger CF is, the larger the range of phase Angle can be set.
IT82150-350-900
Grid parameters
AC input
Wiring
connection
3 phase 3wire +
ground(PE)
Line voltage
RMS
( 200
~
220 ) ±10%
*1
( 380
~
480 ) ±10%
V
Line current
RMS
< 333
A
Apparent power
< 174
kVA
Frequency
45
~
65
Hz
Power factor
typ
0.98
Input parameters
Input voltage
VLN
30
~
350
V
VLL
(
3phase
)
51.96
~
606
V
LL
(
reverse
)
60
~
700
V