Remote Control
Copyright © Itech Electronic Co., Ltd. 5
2
3
4
7
8
9
10
11
12
13
14
15
RS
OP
OT
RUN
EPU
RRV
UNR
LRV
OV
PS
VON
TBF
turned off. Both bits remain set until the condition is removed and INP:PROT:CLE is
programmed.
Remote Sense
when the real pannel sense is connected, this bit is true else false.
Overpower.
An overpower condition has occurred. This occurs if the unit exceeds
the max
power or it exceeds the user-programmed power protection level.
Removing the overpower condition clears the bit. If the condition persists
beyond the user programmable delay time, PS bit is also set and the input is turned
off. Both bits remain set until the condition is removed and INP:PROT:CLE is
programmed.
Over temperature.
An over-temperature condition has occurred. Both this bit and bit
PS are set and the input is turned off. Both bits remain set until the unit is cooled
down and INP:PROT:CLE is programmed.
List run or stop status
when list is running, this bit is true else false.
Extended Power Unavailable.
This bit is not used.
Remote Reverse Voltage.
A reverse voltage condition has occurred on the sense
terminals. Both this bit and VF bit are set. Removing the reverse voltage clears this
bit but does not clear VF bit.VF Bit remains set until INP:PROT:CLE is programmed.
Unregulated.
The input is unregulated. When the input is regulated the bit is cleared.
Local Reverse Voltage.
A reverse voltage condition has occurred on the input
terminals. Both this bit and VF bit are set. Removing the reverse voltage clears this
bit but does not clear PS bit.PS Bit remains set until INP:PROT:CLE is programmed.
Over voltage
. An over voltage condition has occurred. Both this bit and VF bit are set
and the load are turned off . Both bits remain set until the condition is removed and
INP:PROT:CLE is programmed.
Protection Shutdown
. The protection shutdown circuit has tripped because of an
Over-current, over-power, or over-temperature condition. The bit remains set until
INP:PROT:CLE is programmed.
Voltage of sink current on
. When the voltage of input exceeds the user-programmed
Von level, this bit is true else false.
Trace Buffer Full.
Questionable Status Group
Same as Channel Status Group
0
2
3
4
5
7
OPC
QYE
DDE
EXE
CME
PON
Standard Event Status Group
Operation Complete. The load has completed all pending operations. *OPC
must be programmed for this bit to be set when pending operations are
complete.
Query Error. The output queue was read with no data present or the data was
lost. Errors in the range of 499 through 400 can set this bit.
Device-Dependent Error. Memory was lost or self test failed. Errors in the
range of 399 through 300 can set this bit.
Execution Error. A command parameter was outside its legal range,
inconsistent with the load's operation, or prevented from executing because
of an operating condition. Errors in the range of 299 through 200 can set this
bit.
Command Error. A syntax or semantic error has occurred or the load received
a <get> within a program message. Errors in the range of 199 through 100 can
set this bit.
Power-On. The unit has been turned off and then on since this bit was last
read.

Table of Contents

Other manuals for ITech IT8700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT8700 Series and is the answer not in the manual?

ITech IT8700 Series Specifications

General IconGeneral
BrandITech
ModelIT8700 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals