Operation: C12.19 C1SD, C1ST, and C1SL Versions
CENTRON® Meter Technical Reference Guide 61
For meters with batteries, all logged events are retained through a power outage. For meters
without batteries, the Event Log is periodically written to non-volatile memory. Events that
occur just prior to a power outage may be lost depending on whether they were backed-up
or not.
The contents of the event log can be viewed using the meter programming software.
The following events may be configured for recording in the C12.19 C1SD/T/L register
Event Log:
Billing Schedule Expiredbilling schedule has expired and needs to be updated in
PC-PRO+ Advanced
Clear Billing Databilling data has been cleared upon initialization of the meter, or as
a secondary activity by authorized personnel
Configuration Errormeter configuration was not successful
Demand Reset—a demand reset occurred
DST Time ChangeDST adjustment forward or backward has occurred
Event Log Cleared—Event Log was cleared by programming software
Full Scale OverflowNon-Fatal Error Codes for description
Load Profile ErrorNon-Fatal Error Codes for description
Logon Successful—a user or option board logged on successfully to the meter
Low BatteryNon-Fatal Error Codes for description
Meter Reprogrammedmeter was initialized or reconfigured
Power Outagepower was lost
Power Restoredpower was restored
Rate Change—TOU rate change occurred
Register Self Read—self read occurred
Reverse Power FlowNon-Fatal Error Codes for description
Reverse Power Flow Restoreddelivered power flow resumed after reverse flow
exceeded a configured threshold
Season Change—TOU season change occurred
Security Faillogon with security code failed
Security Passlogon with security code succeeded
Test Mode Entered—Test Mode or Alternate Test Mode was entered
Test Mode Exited—Test Mode or Alternate Test Mode was exited
Time Changed—a time adjustment forward or backward occurred
TOU Schedule ErrorNon-Fatal Error Codes for description
Security Codes
Register security can be provided with primary, secondary, and tertiary security codes that
prevent unauthorized communication with CENTRON products. A Primary security code
allows complete access to the meter. A Secondary security code allows full read access with
limited write access to perform an automatic demand reset and to access the Alternate and
Test modes. A tertiary security code allows read-only access. For more information about
security codes, refer to the PC-PRO+ documentation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITRON Centron and is the answer not in the manual?

ITRON Centron Specifications

General IconGeneral
ModelCentron
CategoryMeasuring Instruments
Display TypeLCD
Operating Temperature-40°C to +70°C
TypeElectricity Meter
Communication ProtocolsANSI C12.19
Voltage Rating120V, 240V, 480V
Current Rating200A, 320A
MountingSocket
Accuracy Class0.2, 0.5