Installing 40W and 50W ERT Modules
The tools and material required depend on whether you are installing a direct-mount ERT module or a remote-
mount ERT module; and if it is remote, the way it is mounted (pipe or flat surface). You must supply some or
all of the tools and material listed in Tables 1–2 and 1-3 below. Also, If you remove and replace registers, you
might need tools specified by register manufacturer.
NOTE: For remote-mount installations, customer-supplied cable is required (Badger supplies 3 feet
to 100 feet, typically 25 feet); cable length should not exceed 300 feet (Badger 500 feet). Itron recom-
mends 19-26 gauge, pre-bonded or solid conductor wire with a maximum diameter of .082" (individual
wire with insulation).
Tool or Material Required
Required for
Direct-Mount
or Integral
ERT Modules
Klein model D234-6C pliers, 3M ScotchLok® Model E-9C
Cartridge Tool, or similar tool for crimping wire connectors
Side-cutting pliers for cutting wires, remote cables, and cable
ties (NOTE: Klien model D234-6C pliers satisfy this require-
ment).
Torx® screwdriver, size T-10 security head, for the RTR
mounting setscrew (Badger only)
Torx screwdriver, size T-15 for the screws that attach ERT modules
to integral RTRs and Remote Mounting Brackets
ReadOne® Pro unit for programming and checking ERT modules
Medium flat-blade screwdriver for band clamps
Medium flat-blade, for the screws that attach adapter plates to pipe
brackets and the screws that attach remote mounting brackets to
adapter plates
Cable ties for securing remote cables to pipes or other supports
Standard or long-nose pliers for pulling cable ties tight
1/4-inch nut driver other tool for seating tamper seals
Medium Phillips screwdriver for the screws that attach remote
mounting brackets to wood or sheet-metal surfaces
Table 1-2. Suggested Tool List
XX
X
X
X
X
XXX
X
X
X
XX
X
X
X
X
X
X
X
X
X
X
Mounted on
Pipe
Mounted on Wood
or Sheet Metal
1.7 Tools and Materials You Must Supply
1/16-inch awl for removing tamper seals
Wire strippers for removing insulation from cables and wires
XX X
X
XX
1–7
Required for Remote ERT Modules