Parameter Description
Direct Dialing To extension
prefix
Prefix for direct dialing field – contains the first digit of a target phone
number, to which it is possible to call directly. You can enter up to eight
prefixes using a coma separator.
Example: Defined prefixes 125 enable to dial directly to numbers
beginning with 1, 2 or 5.
Digits defined as a direct call prefix may not be used as first digits for
access door opening code.
The direct dialing feature requires a SIP proxy definition. In case of Peer-
To-Peer mode, VoIP gateway IP address can be used as destination and set
in the SIP proxy address.
Speed Dialing Destination
Numbers (Destination
numbers) 11 – 35
Speed dialing subscribers list – contain from to 2 to 20 lengths of
subscriber’s phone numbers. Legal entry: 0..9, *. It is possible to enter 25
codes indexed from 11 to 35.
If an IP address is used as a destination, use following format:
*XXX*XXX*XXX*XXX, where XXX are digits, the address is prefaced by
an asterisk and an asterisk is used as a separator.
The access door-opening code in speed-dial mode must start with 0.
Call Button Dialing – Day
Mode destination
Day number field – contains the number of the target phone, which will
be dialed when a visitor presses the Call button when the device is
configured to operate in Day mode. You may insert up to 20 entries, so
that a visitor could call different extensions directly. Legal entry: Digits 0-9,
ABCD, *.
Legal entry: from 1 to 15 digits 0-9
Call Button Dialing night
mode destination
Night number field – contains the number of the target phone, which
will be dialed if a visitor will press the Call button when the device is
configured to operate in Night mode. You may insert up to 20 entries, so
that a visitor could call different extensions directly.
Legal entry: digits 0-9, ABCD, *, #.
Legal entry: from 1 to 15 digits 0-9
Call Button Dialing Error
mode destination
Error number field – contains the number of the target phone, which will
be dialed if a visitor will dial an incorrect access entry code more than
three consecutive times. You may insert up to 20 entries.
Legal entry: digits 0-9, ABCD, *, #.
Legal entry: from 1 to 15 digits 0-9