EasyManua.ls Logo

ITW Orbitalum ORBIMAT 165 CA - Operation; Auto Programming

ITW Orbitalum ORBIMAT 165 CA
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ORBIMAT CA | Operating instructions Operation
(09.03.15) OW_ORBIMAT_CA_BA_871060202_04_EN orbitalum tools GmbH, D-78224 Singen, www.orbitalum.com, Tel. +49 (0) 77 31 792-0 29
8. OPERATION
8.1 Auto programming
8.1.1 Setting parameters
1. Connect weld head.
2. Switch on machine.
The main menu appears in the display (see Fig. 5 "Long form").
3. Switch over to the view of the long menu if necessary.
4. 4. Select and highlight the "Auto programming" menu item.
The following display appears:
Field "....":
Return to main menu.
Fields "Weld head model" to "Wall thickness":
Parameter entry.
Field "Wire feed":
Welding with/without filler wire.
"Calculate procedure":
Calculation of the procedure with the entered parameters.
Fig. 9: Sub menu - Auto programming
8.1.2 Configuring weld head
1. Select "Weld head" field and briefly press the rotary knob.
The following display appears:
A list of the weld heads which can be used with this
system appears.
This system automatically detects the type of con-
nected head and offers it for selection first.
In the example, this is an OW 115.
Fig. 10: Selecting a weld head

Table of Contents

Related product manuals