ORBIMAT CA | Operating instructions Operation
(09.03.15) OW_ORBIMAT_CA_BA_871060202_04_EN orbitalum tools GmbH, D-78224 Singen, www.orbitalum.com, Tel. +49 (0) 77 31 792-0 29
8. OPERATION
8.1 Auto programming
8.1.1 Setting parameters
1. Connect weld head.
2. Switch on machine.
The main menu appears in the display (see Fig. 5 "Long form").
3. Switch over to the view of the long menu if necessary.
4. 4. Select and highlight the "Auto programming" menu item.
The following display appears:
Field "....":
Return to main menu.
Fields "Weld head model" to "Wall thickness":
Parameter entry.
Field "Wire feed":
Welding with/without filler wire.
"Calculate procedure":
Calculation of the procedure with the entered parameters.
Fig. 9: Sub menu - Auto programming
8.1.2 Configuring weld head
1. Select "Weld head" field and briefly press the rotary knob.
The following display appears:
A list of the weld heads which can be used with this
system appears.
This system automatically detects the type of con-
nected head and offers it for selection first.
In the example, this is an OW 115.
Fig. 10: Selecting a weld head