ORBIMAT CA | Operating instructions Servicing, maintenance, troubleshooting
(09.03.15) OW_ORBIMAT_CA_BA_871060202_04_EN orbitalum tools GmbH, D-78224 Singen, www.orbitalum.com, Tel. +49 (0) 77 31 792-0 79
Regularly/
As needed
Perform printer maintenance
X Change paper and printer ink ribbon.
Blow out machine
In an extremely dusty environment, it may be necessary to blow out at shorter intervals.
1. Disconnect machine from mains.
2. Loosen the screws located in the hood.
3. For OM 165CA: Also loosen the three screws at the water filling neck and the tank closure.
4. Fold away display.
5. Open hood upward carefully.
6. Screw off the two side panels (incl. the handles) from the side frame if necessary.
7. Blow out/clean machine.
8. Screw side panels back on.
9. Close hood again and screw it tight.
10.1.2 Storage
X If the machine will go unused for a longer period of time, dismantle the machine and store it in a suitable place.
X Recommendation: Carry out the following activities before storage:
1. Clean machine.
2. Remove cooling agent. For this purpose, loosen cooling water return of the weld head on the back of the unit and
pump out coolant supply into a container with the pump.
Storage conditions
Relative humidity <70 %
Temperature range 20 ... +40 °C, protected from dust
10.2 Servicing/customer service
For ordering spare parts, refer to the separate spare parts list.
For troubleshooting, please contact the branch responsible directly.
Please indicate the following details:
Type of machine: ORBIMAT 165 CA, ORBIMAT 300 CA, ORBIMAT 300 CA AC/DC, ORBIMAT 300 CA AVC/OSC
Machine no.: (see type plate)