36
Technical information
Technical information
Factory settings
The table displays the factory values (F value) of the settings that you, as a customer,
(K) can change via the customer menus Menu and Advanced menu. The functions of
Installer/Service level (I/S) under Menu and Advanced menu in the table are accessed by
the installer after changing the access level.
Menu
Level F value
Fast restart of heat pump?
I/S No
Start up
--"--\Setting the clock
--"--\ --"--\Set date I/S
yy-mm-dd
--"--\ --"--\Set time I/S
hh:mm:ss
--"--\Connected extra sensors
--"--\ --"--\T5 acknowledged (T5) I/S No
--"--\Connection capacity (Electric element)
--"--\ --"--\State total output I/S 13,5 kW
--"--\ --"--\Compressor mode, output limitation I/S
4,5/6,75 kW
--"--\ --"--\Additional heat only, output limitation I/S
9,0/13,5 kW
--"--\Manual operation I/S No
--"--\Additional heat options
--"--\ --"--\Additional heat only? I/S No
--"--\ --"--\ Block additional heat? I/S No
--"--\Language I/S Selected
--"--\Correct sensor I/S 0
--"--\Fan defrost interval I/S 1 time
--"--\Fan defrost time I/S 1,0 min
--"--\Forced defrost I/S No
--"--\Block crankcase heater at high outdoor
temperature
I/S 10,0ºC
--"--\Anti-jamming mode time I/S 02:00
--"--\Alarm buzzer signal length I/S 1 min
--"--\T1 Set point value maximum I/S 80ºC
Menu
Level F value
--"--\Display
--"--\ --"--\Contrast I/S 10
--"--\ --"--\Brightness I/S 10
Room temperature setting (T5)
K 20,0ºC
Temperature increase/decrease (ej T5)
K=
Temperature increase/decrease settings (ej T5)
--"--\Limit value for V or H I/S 10ºC
--"--\Much colder/warmer, change I/S 8%
--"--\Colder/warmer, change I/S 3%
Extra hot water
K0 h