M8 Mode
M8 will automacally determine when to turn the pumps on depending on the condions
and the ambient temperature. If the sensors do not detect a decrease in water temperature
from the last me it was checked, M8 will gradually increase the intervals all the way to 2
hours if the condions are very stable.
If a user removes the spa cover for example and the spa temperature starts dropping
significantly, M8 will immediately reduce the checking intervals down to 30 minutes. M8
resets the checking intervals to 30 minutes whenever the user interacts with the system
(acvates equipment, changes heang modes, changes the set temperature etc). Once the
user stops interacng with the system, M8 will resume trying to find the best possible me
and frequency at which the temperature needs to be checked.
When M8 is disabled, the system returns to its normal 30 minute intervals to check the
temperature. When M8 is re-enabled, it resumes it search for an opmized frequency at
which the temperature should be checked.
Incorporang M8 helps to minimize your energy consumpon, supports pump longevity and
helps reduce the frequency of noise associated to the pumps running.