(II)
JWL 7
off: Check weighing under the condition that the weight is within the limits
9. P08: Check Weighing buzzer beep
Hi There will be a warning sound when the weight of articles exceeds the upper limit,
and the weight is equal or more than 20d
LO: There will be a warning sound when the weight of articles exceeds the lower limit, and
the weight is equal or more than 20d
okThere will be a warning sound when the weight of articles is between the upper and
lower limit (including the upper and lower limits), and the weight is equal or more than 20d
outThere will be a warning sound when the weight of articles is beyond the upper &
lower limit, and the weight is equal or more than 20d
no.beep no beep
10. P09: External device
= Birch printerBP545,TDP643
= Godex printer
= Zebra printer
= Dot matrix printerCK,SH-24
=Large LED display
=Computer
=Connecting the weighing managing system
= CX large screen display(version 0.02)
= Thermal printer(Chinese available)
=the output format is compatible with Toledo Continuous Mode
Note: Special setting is needed by distributor if you want to print in Chinese.
= Work with the function of “Use Serial Keys” in Windows in outputting the data to
Excel. Reference user manual: http://www.jadever.com.cn/Download.aspx
11. P10: RS-232 Serial Transmission Rate
960048002400
12. P11: Print mode
continContinuous print