Page 23
Section 5. Operating Instructions
Indicates level of chlorine
output production.
Each light represents a
20% production
Check salt level indicator
Indicates that there
is not enough ow
through the cell
5.2 Turning Power Pack On/Off (Manually)
ToturntheJandy®AquaPure®Eichlorinegeneratingdeviceonoroffpressthe button.
NOTE: Becausethepowerpackiswiredtothepump’spowersource,thepowerpackcanonlybeturnedonwhen
thepumpisturnedon.
5.3 Turning Power Pack On/Off (Using the Pump’s External Timer)
Ifthepowerpackiswiredtothepump’sexternaltimerandthepowertothepowerpackison,thepowerpackwill
automatically turn on and off when the pump turns on and off (see Section 3.3). When the power pack is wired as
such,theonlysettingthatmustbesetmanuallyisthechlorineoutputlevel(seeSection5.4).
5.4 Setting the Chlorine Output Level
Whensettingthechlorineoutputlevelyoumustconsiderthesizeofthepool,theamountofusethepoolwillbe
receiving and how hot the weather is. All these factors weigh greatly on the level of output needed. To adjust the
output level, follow these steps:
1. Turn the power pack on by pressing the
button.
2. Press the
button to reach the desired output level. The minimum setting is 20% (one amber light). The
outputcanbeadjustedinincrementsof20%upto100%.IftheOUTPUTbuttonispressedbeyond100%,the
output level setting will drop back to 20%.
Figure 24. Control Panel on the Power Pack
Output Setting Amount of time cell will run
20%-one(1)light Cellwillruntwo(2)min.everyten(10)min.
40%-two(2)lights Cellwillrunfour(4)min.everyten(10)min.
60%-three(3)lights Cellwillrunsix(6)min.everyten(10)min.
80%-four(4)lights Cellwillruneight(8)min.everyten(10)min.
100%-five(5)lights Cellwillrunnon-stop.
5.1 Control Panel
WARNING
Toavoidpropertydamage,seriousinjuryordeath,donotoperatetheelectrolyticcellwithoutwatercirculation.Abuildupof
ammablegasseswhichcanresultinFIREOREXPLOSION.