5.5 Connection to an AquaLink® RS / PDA Control System
TheJandy®AquaPure®EichlorinegeneratingdevicecanbeconnectedtoanAquaLinkRSorPDAControlSystem.
SeeSection3.5and3.6.FordetailedinstructionsfortheAquaLinkRSorPDAControlSystem,seetherespective
manuals.
5.6 Polarity Reversal
TheJandyAquaPureEichlorinegeneratingdeviceisareversablepolaritycellwhichmeansthatforeveryve(5)
hours of operation the cell will switch its polarity to help prevent any build up of calcium on the cell plates. This is
sometimes referred to as the automated cell cleaning feature. During the transition between changing its polarity there
isave(5)minutewaittimewhenthecellwillnotproduceanychlorine.Onceithaschangedpolarityitwillcontinue
to make chlorine.
NOTE: ‘CLEANING’willbedisplayedonthescreenduringtheve(5)minute‘WAIT’period.Theoutput
levelindicatorwillremainassetduringthecleaningperiod).
5.7 Backup Battery
Thepowerpackisttedwitharechargeablebatterywhichcanlastinexcessof500hourswithoutthepowerbeing
connected.IntheeventofapowerfailurethebatterywillretainALLsettings.
In the event of the battery losing its charge, the microprocessor in the unit will retain the following settings
permanently:
• Operatinghours
• Cellhours
• Controllersetting