Page 8
Section 2. System Description
Figure 1. Example of Installation
2.1 Product Specications
Maximum Operating Pressure: 50psi Input Current @ 240 VAC: ~1 A
Input Current @ 120 VAC: ~1.3 A
Minimum Flow Rate: 40gpm
Maximum Flow Rate: 92gpm Input Freq: 47~63Hz
Required Salt Level: 4,000ppm(4.0gpl) Output Voltage: 25VDC(max)
Maximum water volume treated:
APURE35-35,000gal.(132,000L)
Output Current (adjustable by switch):
APURE35 - 5ADC
Chlorine Output:
APURE35 - 0.62oz.(17.5g)perhour
Dimensions:
Power Pack (L x W x H):10in.x4.5in.x13in.
Electrolytic Cell (L x W x H):6.5in.x5.5in.x12in.
Input Voltages: 240Vor120V
(thesystem
auto-detectsvoltage)
Weight:
Power Pack:7lbs.
Electrolytic Cell:2lbs.
The cell must be installed as the
last piece of equipment in the
circulation plumbing system just
before the pool
Cell
Heater
Pump
To common
power source
Power Pack
Filter
Pool Intake Spa Intake
Spa ReturnPool Return