Problem PossibleCause
CorrectiveAction
NodisplayonLCD(screenisblank). Nopowertounit. Checktheconnectiontothepump
timer(seeSection3.4).
Problem PossibleCause
CorrectiveAction
Flowlightison(Displaysays“NoFlow”).
Causedbyinsufcientwaterowthrough
thecell.
NOTE: WhentheFlowlightison,
thechlorineoutputwillbe
turnedoff.
Filterisdirty. Cleanthelter.
Closedvalves. Checkandcorrectallvalve
alignments.
Pumpfailstoprovide
sufcientwaterow.
Checkforcorrectoperationofthe
pump.Ensurethereisnolossof
pumpprimeorcloggedstrainer
baskets.
Problem PossibleCause CorrectiveAction
Saltlightison(Displaysays“CheckSalt”).
NOTE: TheSaltlightwillturnon
whenthesaltleveldrops
below3,000ppmanditwill
remainonuntilthesaltlevelis
raisedabove3,500ppm.
Saltlevelislessthan3,000
ppm,dependingonwater
temperature.
Maintainasalinitylevelof
4,000ppm-4,500ppm
(seeSection4.7orcontact
yourlocalpoolprofessional).
Acombinationofextremely
lowwatertemperature(close
tofreezing)andlowsaltlevel
(~3,500ppm).
Maintainasalinitylevelof
4,000ppm-4,500ppm
(seeSection4.7orcontact
yourlocalpoolprofessional).
Celllifeexpired. Replacethecell.
Problem PossibleCause CorrectiveAction
“OutputFault”appearsonthescreen. Powersupply. Turnthepowerofftothepowerpack
andconsultyourlocalpoolcare
professional.