P310
Frequency of low analog
Setting Range: 0~400.0 Unit:0.1
Factory Setting: 0.0
P311 Direction of of low analog
Setting Range: 0~1 Unit:1
Explanation: 0: Positive direction
1: Negative direction
Factory Setting: 0
P312 Frequency of high analog
Setting Range:0~400.0 Unit:0.1
Factory Setting: 50
P313 Direction of high analog
Setting Range: 0~1 Unit:1
Explanation: 0: Positive direction
1: Negative direction
Factory Setting: 0
P314 Analogue reverse options
Setting Range: 0~1 Unit:1
Explanation: 0: No reverse at negative bias voltage
1: Reverse allowed at negative bias
The parameter group of P310-P314 decides the running condition of analogue,
including output frequency and direction. According to actual need of user, they
can form various control curves.
Factory Setting: 0
6
Chapter 6 Description of parameter setting
FC100 Series User Manaul