Default value 100
Reaching frequency 1
P425
Setting Range:0~Max frequency Unit:0.1
Default value 5.0
Reaching frequency 2
P426
Setting Range:0~Max frequency Unit:0.1
FC100 Series set two groups of frequencies arrive,when output
frequency arrive the setting value of P425 and P426,corresponding
multi-function output terminal is ON. Frequency arrive width is of a
hysteresis loop,which is set by P430
Default value 0
No. 1 timer
P427
Setting Range:0~10.0S Unit:0.1
Default value 0
P428
Setting Range:0~100S Unit:1
No. 2 timer
FC100 series have two timers, when time of the timers reaches setting
value (set by P427 and P428), corresponding multi-function terminal
is ON.
Timer start is controlled by external multi-function input terminal.
Some simple program may be made by using these two timers.
6
Chapter 6 Description of parameter setting
FC100 Series User Manaul