For example: there is a five-segment rate, the circling running is required as
follow:
Items
Output frequency
Running direction
Running duration
Dominant
frequency
Potentiometer is
adjustable
Forward
Segment 1
20.0
Reverse
20
Segment 2
60.0
Forward
25
Segment 3
40.0
Reverse
30
Segment 4
15.0
Forward
20
Two buttons, one is for running, the other one is for ceasing; the main frequency
requires adjustable potentiometer.
(1) Connection illustration
(2) PLC operation direction setting: (P533 setting)
Rate of
segment
1
Rate of
segment
2
Rate of
segment
3
Rate of
segment
4
Dominant
frequency
4 3
2
1
0
0 1
0
1
0
0x24
1x23
0x22
1x21
0x20
position (bit)
run direction <0 is
forward, 1 is Reverse
transfer to decimal
system
6
Chapter 6 Description of parameter setting
FC100 Series User Manaul