Fault Probable Cause Action
8 Hydraulic oil becomes too hot Oil cooler obstructed Remove debris from cooler matrix fins.
Restriction in neutral circuit Check hoses, replace as necessary
lines
Hydraulic filter clogged and Change hydraulic filter.
by-pass valve not working