2 - 3
Syncro Shuttle (cont'd)
Converter Pressures (in neutral) bar kgf/cm
2
lbf/in
2
Converter In at 50 deg.C 1000 rev/min 2.4 - 3.4 2.5 - 3.5 35 - 50
2000 rev/min 5.2 - 6.5 5.3 - 6.7 75 - 95
Converter In at 100 deg.C 1000 rev/min 1.3 - 2.0 1.4 - 2.1 20 - 30
2000 rev/min 5.2 - 5.9 5.3 - 6.0 75 - 85
Converter Out (measure at 50 deg.C and 2000 rev/min) 3.4 3.5 50 max
Converter Relief (Safety) Valve Pressure 6.5 6.7 95 max
Lubrication Pressures (in neutral)
At 50 deg.C 1000 rev/min 0.2 - 0.3 0.2 - 0.4 3.0 - 5.0
2000 rev/min 0.4 - 0.7 0.4 - 0.7 6.0 - 10.0
At 100 deg.C 1000 rev/min 0.1 - 0.2 0.1 - 0.2 2.0 - 3.0
2000 rev/min 0.3 - 0.6 0.3 - 0.6 4.0 - 8.0
Main Line Pressure (in neutral)
At 50 deg. C 1000 rev/min 9.3 - 10.3 9.5 - 10.5 135 - 150
2000 rev/min 10.7 - 11.7 10.9 - 12.0 155 - 170
At 100 deg.C 1000 rev/min 9.3 - 10.3 9.5 - 10.5 135 - 150
2000 rev/min 9.3 - 10.3 9.5 - 10.5 135 - 150
Clutch Pressure (forward and reverse) â€
At 50 deg. C 1000 rev/min 7.6 - 9.7 7.7 - 9.8 110 - 140
2000 rev/min 9 - 11 9.1 - 11.25 130 - 160
At 100 deg.C 1000 rev/min 7.6 - 9.7 7.7 - 9.8 110 - 140
2000 rev/min 7.6 - 9.7 7.7 - 9.8 110 - 140
†Note: The forward and reverse clutch pressures should always be the same as the mainline pressure less (a maximum of)
1.7bar (25lbf/in
2
; 1.8kgf/cm
2
). If the mainline pressure is in the lower part of the tolerance band, then the forward and reverse
clutch pressures should also be in the lower part of the tolerance band and vice versa.
Flow Rates (in neutral) litres/min UK gal/min US gal/min
Cooler at 50 deg.C 1000 rev/min 10.4 - 13.6 2.3 - 3.0 2.8 - 3.6
2000 rev/min 14.5 - 20.0 3.2 - 4.4 3.8 - 5.3
Cooler at 100 deg.C 1000 rev/min 10.2 - 12.5 2.3 - 2.8 2.7 - 3.3
2000 rev/min 22.7 - 26.1 5.0 - 5.7 6.0 - 6.9
Pump at 50 deg.C 1000 rev/min 11.0 - 15.0 2.5 - 3.3 2.9 - 4.0
2000 rev/min 22.5 - 29.5 5.0 - 6.5 6.0 - 7.8
Section F Transmission
9803/7130
Section F
2 - 3
Issue 1
Technical Data