The following electronic throttle specification must be complied with:
Temperature Range
Operating: -40°C to +85°C
Storage: -50°C to +105°C
Functional Life
Full cycles (full rotation): 30 000 000
Dither (2 degrees rotation): 100 000 000
Electrical Specifications for Ratiometric Voltage Output
Supply (Reference)
Voltage Operating: 5 V ±0.5 V
Supply Over voltage
Cont. max.: +16 V, -15 V for min. 1 min @ +25°C ±14.4 V for min 10 min.
Supply Current Draw: max. 10 mA per Output
Sensor Hysteresis: max. ±1% of supply voltage
Sensor Linearity: See Figure 29
Minimum Load Resistance: >30 kΩ
Maximum Load Capacitance: <1000 nF
Output short circuit: unlimited time
Output time response: max. 10 ms
Power-up time: max. 50 ms
Environmental Specification
EMC: 150 V/m
ESD: ±15 kV
Seal Compliance: IP67
Chemical Resistance as per. SAE J1455
13.7.2 Engine Fixed Speed Control (EFSC)
This feature is enabled in the ECU software for all IPU applications. The EFSC system can
be set On or Off, with a range of set speeds and choice of increment and decrement step
sizes.
This system needs electrical switches to be connected to three pins on the engine ECU. This
feature cannot be used in conjunction with two twin track control devices. Please contact
your JCB Power Systems Applications department for more information and advice.