JCB EcoMAX Engine Installation Manual
© JCB Power Systems Ltd. 320/A9164-1 Page 47 of 64
16. Delegated Assembly Approval
For engines that are to enter the US or EU the delegated assembly must be adhered to.
Deviation from the design is not permitted. The EcoMAX T4 IPU is supplied with all the
delegated assembly components mounted either to the engine or the tank module. If the
engine and tank module are not installed into a machine, both the engine and the tank
module must be shipped on a single pallet to ensure that the delegated assembly is retained.
The components supplied on a single pallet must be fitted to the same machine,
components cannot be ‘mixed and matched’. An agreement must be signed by the OEM to
state that components will not be changed.
17. Aftertreatment Components Installation
17.1 Introduction
To reduce the installation design and validation activity required by the OEM, JCB have
packaged two options of Tank Module which are an integrated solution for the remainder of
the system components built into a single unit.
This chapter details the installation requirements and instructions for mounting the Tank
Module within the equipment.
If the OEM does not follow these instructions when installing a certified engine in a piece of
non-road equipment it violates federal law (40 CFR 1068.105(b)), subject to fines or other
penalties as described in the Clean Air Act.
17.2 Using these instructions
This section is arranged to give a good understanding of the JCB aftertreatment system and
guidance on its safe integration into equipment. Its primary purpose is to assist engineers
and designers specialising in installing JCB EcoMAX engines into equipment. It gives advice
on good practice together with requirements to give the expected operation and
aftertreatment system life. Adherence to the advice contained in this manual will help ensure
acceptance of the installation by JCB Power Systems.
Fully read this section before installing the aftertreatment system into equipment. The OEM
must follow all of the safety aspects of the installation. The OEM must make sure that they
give users of equipment adequate instruction for safe operation of the equipment including
an Operator’s Manual, warnings, and labelling as required.
Throughout this section there are safety messages. Please read and understand these
safety messages before installing the engine into equipment.
For more advice and guidance consult JCB Power Systems Applications department.

Table of Contents