Page 15 of 47
2 – SAFETY INFORMATION
_____________________________________________________________________________________________
2.4 Dangerous zones
There are some very dangerous zones near the machine.
The dangerous zone is determined by the field of action of the crane.
It is absolutely forbidden to stay under hanging loads
There could be further dangers in the w orking area: please, observe the follow ing rules
Don't work near electric wires, danger of death in case of contact
with electric wires. While working, keep the following minimum
distance from the power line:
Volt (KV) Min dist. Insulated electric wire (M)
<1 3 (9.8 ft
10 3.5 (114.8 ft
15 3.5 (114.8 ft
132 5 (16.4 ft
220 7 (23 ft
2.5 Emergency stop
Note: This procedure can be performed in any moment.
In compliance w ith the safety rules in force, the machine has been provided w ith emergency devices.
They must be operated to reduce the stopping time w hen the usual stop procedure would not enable
actual or impending danger to the operator or to the machine itself to be averted.
CAUTION!!!
Before putting the machine back into service, remove the cause of danger.
Location of emergency devices
The machine has been provided w ith several types of emergency devices.
• Emergency push-button - located on main switchboard
• Emergency push-button - located on radio remote control
About emergency devices
The main features of the installed emergency devices are:
Mushroom-shaped emergency push-button;
PUSH the mushroom-shaped button to stop the machine.
Machine back into service after emergency
https://cranemanuals.com